Meter
50 - 0 - 50 vdc |
 |
|
(MTR) MR26B5T5DCV
A&M center scale volt meter.
Great for dual power supply. Actual fs = 150mv. 2-3/4" diameter
face. 2" hole. |
|
|
Meter
0 - 50 vdc |
 |
|
(MTR) SK333PC9
A&M DC voltmeter can be used
for monitoring 12 - 50 vdc sources. 3-1/2" diameter, 2-3/4" mounting
hole. 2" behind panel. |
|
|
|
| **SALE PRICE**
$25 each - $21 (10+) |
|
|
|
|
Meter
0 - 50 vdc |
 |
(MTR) 7140
Simpson DC volt meter. 1k ohm/V.
3-1/2" diameter face. 2-3/4" hole. 2" behind
panel. |
|
|
Meter
0 - 50 vdc |
 |
(MTR) 53SN
Honeywell meter with 3" square
bakelite case. 2-3/4" mounting hole. 2" behind panel
clearance. |
|
| |
|
|
DC Volt Meter
0 - 50 vdc |
 |
|
(MTR) 1931-S-809
Sun Electric Corporation DC volt meter. 0 - 50 vdc. Model 1931. 3-1/2" diameter body, 2" behind panel depth. |
|
|
DC Volt Meter
0 - 50 vdc |
 |
|
(MTR) 1327-50VDC
Simpson DC volt meter. 0 - 50 vdc. Model 1327, Catalog 9780. 1k ohms / volts. Wide VUE annular. 3-1/4" x 3-1/4", 2" behind panel depth. |
|
|
|
DC Volt Meter
0 - 150 vdc |
 |
|
(MTR) 135-0472
Vertical edgewise rear panel mount. Meter movement 1 mA. Taps for 0 - 15 vdc or 0 - 150 vdc. 1,000 ohms / volts. 15/16" wide x 13/16" high
window. |
|
|
Meter
0 - 75 vdc |
 |
|
(MTR) S3/243
Wilbac ammeter, 0 - 75 vdc. 1000 ohm / v. 3" x 3-1/2" face.
2-1/8" hole required. 1-1/2" behind panel depth. |
|
|
|
|
Weston Lab Meter / DC Volts
0 - 7.5v / 0 - 30v / 0 - 75v |
 |
|
(MTR) 931-75VDC
Weston lab meter, DC volts. 0 - 7.5 - 30 - 75 vdc scale. Separate input terminals. Leather handle. Black bakelite case. 0 - 7.5v, 0 - 30v, 0 - 75v. 5" x 3-1/4" x 5-1/4"H. |
|
|
Weston Lab Meter / DC Volts
0 - 3.0v / 0 - 15v / 0 - 150v
|
 |
|
(MTR) 931-150VDC
Weston lab meter, DC volts. 0 - 3 - 15 - 150 vdc scale. Separate input terminals. Leather handle. Black bakelite case. 0 - 3.0v, 0 - 15v, 0 - 150v. 5" x 3-1/4" x 5-1/4"H. Only one available. |
|
|
|
Meter
0 - 150 vdc |
 |
|
(MTR) 27-150VDC
Simpson panel meter. Model 27. 0 - 150 vdc. 1k ohms / volts. 3" x 3-1/8"H, 2-1/8" behind panel depth. New in the box!! |
|
|
Weston Lab Meter / DC Volts
0 - 150v / 0 - 300v / 0 - 750v
|
 |
|
(MTR) 931-750VDC
Weston lab meter, DC volts. 0 - 150 - 300 - 750 vdc scale. Separate input terminals. Leather handle. Black bakelite case. 0 - 150v, 0 - 300v, 0 - 750v. 5" x 3-1/4" x 5-1/4"H. Only one available. |
|
|
|
DC Volt Meter
0 - 200 vdc |
 |
|
(MTR) 29-200VDC
Simpson DC volt meter. Model 29. 0 - 200 vdc. 1k ohms / volts. 4" x 4-1/2", 1-3/4" behind panel depth. |
|
|
Meter Relay
400 - 700 vdc |
 |
|
(MTR) 25-5932-4903
API meter relay is sealed and shielded. "400
- 700 vdc" scale with adjustable high and low limit set points. Actual full scale
= 500 µADC (41 - 74 ma). 2-3/4" diameter face, 2-1/8" hole required.
1-7/8" behind panel. |
|
|
|
Voltmeter
0 - 500 vdc |
 |
|
(MTR) 66252311624
Honeywell model 535N meter reads 0 - 500 vdc. 3" square, 2-3/4"
hole required. 2" behind panel depth. |
|
|
Meter
0 - 800 vdc |
 |
|
(MTR) 94-549-18
Panel meter. 0 - 800 vdc (direct reading) high quality panel meter. Includes hardware. 2-3/4" wide x 2-1/2" high x 2" deep. |
|
| |
|
|
Meter
0 - 5,000 vdc |
 |
|
(MTR) 50-152119CYZZ2
General Electric panel meter. Model 152. 0 - 5 kilovolts DC. FS = 1 madc. 2-3/4" x 2-3/4" x 2-1/4" deep. 3 mounting studs. Requires 2" diameter hole. Harris P/N: 632-0808-000. |
|
|
Meter Relay
0 - 10 kv DC |
 |
| |
(MTR) 253071-2503
API meter relay is sealed and shielded . "0
- 10 kv dc" scale with adjustable high limit set point. Actual full scale = 0
- 10v. 2-3/4" diameter
face, 2-1/8" hole required. 2" behind panel. |
|
| |
|
|
Panel Meter
0 - 6 kv / 0 - 12 kv |
 |
|
(MTR) 632-0334
Simpson panel meter. 0 - 6 kv, 0 - 12 kv. FS = 1 ma. 3" x 3" x 2" behind panel depth. Requires 2-3/4" diameter hole. Harris P/N: 632-0334. |
|
|
Panel Meter
0 - 12 kv |
 |
|
(MTR) 841723
Modutec panel meter. 0 - 12 kv scale. FS = 1 ma. 4" x 5" x 1-5/8" deep. Requires 2-5/8" diameter hole. Harris P/N: 632-0947-000. |
|
| |
|
Meter Relay
0 - 15 kv DC |
 |
| |
(MTR) 35-00232503
API meter relay is sealed, shielded and ruggedized. "0
- 15 kv dc" scale with adjustable high limit. Actual full scale = 0 - 1 mADC.
3-1/2" diameter
face, 2-9/16" hole required. 2-1/4" behind panel. |
|
|
Meter
0 - 20 kvdc |
 |
|
(MTR) 842-202
Modutec panel meter. 0 - 20 DC kilovolts. FS = 100 µadc. 4" x 5" x 1-5/8" behind panel depth. Requires 2-5/8" hole. Harris P/N: 632-09555-000. |
|
|
|
Meter
0 - 20 kvdc |
 |
|
(MTR) 841-19769
Phaostron meter with "0 - 20 kvdc" scale.
Actual full scale = 1 mADC. 4" x 4-1/2", 2-5/8" mounting hole. 1-7/8" behind
panel. |
|
|
Meter
0 - 50 kv DC |
 |
|
(MTR) 1751-91
Weston 50 kvdc. 200 µa full
scale. Requires bleeder resistor. |
|
|
|
|
HV Voltage Meter Multiplier
Field Replacement Kit |
 |
|
(GAT) 994-8166
High voltage meter multiplier field replacement kit for Harris 30 kw Klystron amplifier. BT20U / BT30U / BT60U. Harris P/N: 994-8166-001. |
|
|
Digital Voltmeter
Reads 100 mv, 1v, 10v, 100v, 1 kvdc |
 |
|
(MTR) PM4100VDC
NLS 4-1/2 digit LED meter reads 100 mv, 1v,
10v, 100v, 1 kvdc. Instructions included. 2-7/8" wide x 15/16" high, 3-1/2" behind
panel. |
|
| |
| |
SSL
|